manufacturer 21/35 kv cable underground copper conductor 1 3 core 150mm2 180mm XLPE power cable
Introduction:
For XLPE insulated power cable, either chemical method or physical method is employed to transform the molecular structure of PE from chain into three-dimensional network, i.e. thermo-plastic PE is transformed into thermosetting XLPE. After cross-linking, the thermal and mechanical properties of PE have been greatly improved while its excellent electrical property are still retained.
The maximum permissible operating temperature of the conductor of an XLPE insulated power cable is 90°C, which is higher than that of paper, PVC, or PE insulated power cable. The cable has the advantage of simplicity in construction, lightness in weight, convenience in application besides its excellent electrical, thermal, mechanical, and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.
The mechanical and electrical properties of these cables are accordant with GB/T12706-2002 Power cables extruded insulation and their accessories of related voltages 1kV(Um=1.2kV) up to 35kV(Um=40.5kV) and IEC60502-1997 Extruded insulation power cables and appendices for rated voltages 1kV up to 30kV.
Description:
1) Rated Voltage: 21/35KV
2) Max. working temperature: 90 °c
3) Max. temperature during short circuit (≤5S): 250 °c
4) Conductor: class 1, 2 copper or aluminum
5) Sectional area: 1×50 – 1200mm2, 3×50 – 400mm2
6) Insulation: XLPE
7) No. of cores: 1, 3
8) Armor: steel wire or steel tape for 3 core cables and non-magnetic material for single core
9) Oversheath: PVC/XLPE
10) Min. bending radius: 15 times cable radius for single-core cables and 12 times for multi-core ones
11) Max. conductor DC resistance at 20°c:
Standard:
IEC 60502, 60228, 60332, 60331
DIN VDE 0276-620
HD 620 S1: 1996
DIN EN 60228 class 2 (construction)
Application:
Type | Conductor | Application |
YJV/YJLV | CU/AL | For laying in door, tunnel, channel and underground. Unable to bear external mechanical force, but bear the traction force during laid. |
YJV22/YJLV22 | CU/AL | For laying in tunnels in door, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force. |
YJV32/YJLV32 | CU/AL | For laying in shaft with large difference of level. Able to bear external mechanical force and moderate pulling force. |
Technical Parameters:
Nominal cross-sectional area of conductor(mm²) | Insulation thickness (mm) | Sheath thickness (mm) | Approx. overall diameter of cable(mm) | Approx. weight Of cable (kg/km) | D.C resistance of conductor(Ω/km) | Testing voltage A.C | Current rating | |||||
In air(A) | Direct in soil(A) | |||||||||||
Cu | AI | Cul | Al | (kV/5min) | Cu | Al | Cu | Al | ||||
1 x 50 | 9.3 | 2.0 | 37 | 1609 | 1360 | ≤0.387 | ≤0.641 | 73.5 | 220 | 170 | 215 | 165 |
1x 70 | 9.3 | 2.5 | 38 | 1850 | 1471 | ≤0.268 | ≤0.443 | 73.5 | 270 | 210 | 265 | 200 |
1 x 95 | 9.3 | 2.5 | 40 | 2193 | 1605 | ≤0.193 | ≤0.32 | 73.5 | 330 | 255 | 315 | 240 |
1x 120 | 9.3 | 2.5 | 42 | 2498 | 1756 | ≤0.153 | ≤0.253 | 73.5 | 375 | 290 | 360 | 270 |
1x 150 | 9.3 | 2.5 | 44 | 2830 | 1910 | ≤0.124 | ≤0.206 | 73.5 | 425 | 330 | 400 | 305 |
1x 185 | 9.3 | 2.5 | 45 | 3248 | 2102 | ≤0.0991 | ≤0.164 | 73.5 | 485 | 380 | 455 | 345 |
1 x 240 | 9.3 | 2.5 | 48 | 3881 | 2395 | ≤0.0754 | ≤0.125 | 73.5 | 560 | 435 | 525 | 400 |
1 x 300 | 9.3 | 3.0 | 50 | 4529 | 2672 | ≤0.0601 | ≤0.100 | 73.5 | 650 | 510 | 595 | 455 |
1 x 400 | 9.3 | 3.0 | 53 | 5570 | 3094 | ≤0.047 | ≤0.0778 | 73.5 | 760 | 595 | 680 | 525 |
1 x 500 | 9.3 | 3.0 | 55 | 6690 | 3595 | ≤0.0366 | ≤0.0605 | 73.5 | 875 | 690 | 775 | 600 |
1 x 630 | 9.3 | 3.1 | 60 | 8099 | 4193 | ≤0.0283 | ≤0.0469 | 73.5 | 1000 | 800 | 875 | 680 |
1 x 800 | 9 3 | 3.1 | 65 | 9752 | 4792 | ≤0.0221 | ≤0.0367 | 73.5 | 1130 | 920 | 970 | 770 |
1x 1000 | 9.3 | 3.2 | 70 | 11781 | 5581 | ≤0.0176 | ≤0.0291 | 73.5 | 1250 | 1040 | 1060 | 860 |
1x 1200 | 9.3 | 3.3 | 74 | 13784 | 6344 | ≤0.0151 | ≤0.0247 | 73.5 | 1350 | 1130 | 1120 | 920 |
3×50 | 9.3 | 3.5 | 76 | 4817 | 4492 | ≤0.3870 | ≤0.6410 | 73.5 | 185 | 145 | 200 | 170 |
3×70 | 9.3 | 3.6 | 80 | 5668 | 5000 | ≤0.2680 | ≤0.4430 | 73.5 | 230 | 190 | 250 | 190 |
3×95 | 9.3 | 3.7 | 83 | 6642 | 5533 | ≤0.1930 | ≤0.3200 | 73.5 | 280 | 215 | 300 | 230 |
3×120 | 9.3 | 3.8 | 86 | 7603 | 6054 | ≤0.1530 | ≤0.2530 | 73.5 | 310 | 240 | 330 | 255 |
3×150 | 9.3 | 3.9 | 89 | 8678 | 6593 | ≤0.1240 | ≤0.2060 | 73.5 | 360 | 280 | 380 | 295 |
3×185 | 9.3 | 4.0 | 93 | 9965 | 7255 | ≤0.0991 | ≤0.1640 | 73 5 | 400 | 310 | 425 | 330 |
3×240 | 9.3 | 4.2 | 98 | 11914 | 8216 | ≤0.0754 | ≤0.1250 | 73.5 | 470 | 365 | 490 | 380 |
3×300 | 9.3 | 4.3 | 102 | 14026 | 9248 | ≤0.0601 | ≤0.1000 | 73.5 | 540 | 430 | 555 | 435 |
3×400 | 9.3 | 4.6 | 110 | 17266 | 10663 | ≤0.0470 | ≤0.0778 | 73.5 | 610 | 485 | 625 | 500 |